Issue Potential Causes Recommended Actions
/DPSGRHVQRWWXUQ
21
Electronic Control does not
ZRUN'XHWR2YHU9ROWDJH
D3UHVVLQJDQ\NH\WKH/&'OLJKWVXSDQG,FRQVDUHLQSODFH"
Yes, Proceed with the following diagnostic sequence
No, Replace the control and user interface.
7KHODPSZDVQRWVFUHZHG
correclty
5HPRYHODPSFRYHU
6FUHZWKHODPSXQWLOLWUHDFKHVWKHHQGRIWKHVRFNHW
9HULI\
Non functional lamp 5HPRYHWKHODPS
9HULI\WKHODPSWREHQRQIXQFWLRQDOUHYLHZLQJWKDWWKH¿ODPHQWLV
not burned and be in correct place.
5HSODFHLIQHHGHG
9HULI\
During the hood cleaning, the
motor connector has been loose
and a false contact in the main
harness is performed.
2SHQWKHFRQWUROER[UHPRYLQJWKHVFUHZV
5HPRYHSRZHUVXSSO\IURPWKHKRRG
9HULI\WKDWWKHFRQQHFWRUFRPLQJIURPWKHPRWRULVZHOOFRQQHFWHG
to the connector mounted in the plastic verifying that the locking
system in the connectors is well locked.
,IWKHFRQQHFWRUVDUHQRWZHOOFRQQHFWHG
+ROGDQGSUHVVPDLQFRQQHFWRUVDWWDFKHGLQWKHZKLWHSODVWLF
3XVKLQZDUGVWKHPRWRUODPSFRQQHFWRUVXQWLOWKHORFNLQJV\VWHPRQ
connectors is well attached.
&RQQHFWKRRGWRSRZHUVXSSO\DQGYHULI\
)$1GRHVQRWZRUN
Electronic Control does not
ZRUN'XHWR2YHU9ROWDJH
D3UHVVLQJDQ\NH\WKH/&'OLJKWVXSDQG,FRQVDUHLQSODFH"
Yes, Proceed with the following diagnostic sequence
No, Replace the control and user interface.
During the hood cleaning, the
motor connector has been loose
and a false contact in the main
harness is performed.
2SHQWKHFRQWUROER[UHPRYLQJWKHVFUHZV
5HPRYHSRZHUVXSSO\IURPWKHKRRG
9HULI\WKDWWKHFRQQHFWRUFRPLQJIURPWKHPRWRULVZHOOFRQQHFWHG
to the connector mounted in the plastic and that the locking system in
the connectors is well locked.
,IWKHFRQQHFWRUVDUHQRWZHOOFRQQHFWHG
+ROGDQGSUHVVPDLQFRQQHFWRUVDWWDFKHGLQWKHZKLWHSODVWLF
3XVKLQZDUGVWKHPRWRUODPSFRQQHFWRUVXQWLOWKHORFNLQJV\VWHPRQ
connectors is well attached.
&RQQHFWKRRGWRSRZHUVXSSO\DQGYHULI\
7KHEORZHULV
too noisy
Filters are dirty 9HULI\WKDWWKHJUHDVHDQGRUFKDUFRDO¿OWHUVDUHFOHDQ
,IWKH\DUHQRWFOHDQFKDQJHFKDUFRDO¿OWHURUZDVK
JUHDVH¿OWHUDQGYHULI\
False contact in the
connectors
During the hood cleaning, the
motor connector has been loose
and a false contact in the main
harness is performed.
2SHQWKHFRQWUROER[UHPRYLQJWKHVFUHZV
5HPRYHSRZHUVXSSO\IURPWKHKRRG
9HULI\WKDWWKHFRQQHFWRUFRPLQJIURPWKHPRWRULVZHOOFRQQHFWHG
to the connector mounted in the plastic and that the locking system in
the connectors is well locked.
,IWKHFRQQHFWRUVDUHQRWZHOOFRQQHFWHG
+ROGDQGSUHVVPDLQFRQQHFWRUVDWWDFKHGLQWKHZKLWHSODVWLF
3XVKLQZDUGVWKHPRWRUODPSFRQQHFWRUVXQWLOWKHORFNLQJV\VWHPRQ
connectors is well attached.
&RQQHFWKRRGWRSRZHUVXSSO\DQGYHULI\
7KHKRRGDQGRU
the lamp does not
work
$WHUPLQDORUFRQQHFWRULVORRVH
2SHQWKHFRQWUROER[UHPRYLQJWKHVFUHZV
5HPRYHSRZHUVXSSO\IURPWKHKRRG
9HULI\WKDWWKHFRQQHFWRUFRPLQJIURPWKHPRWRULVZHOOFRQQHFWHG
to the connector mounted in the plastic and that the locking system in
the connectors is well locked.
,IWKHFRQQHFWRUVDUHQRWZHOOFRQQHFWHG
+ROGDQGSUHVVPDLQFRQQHFWRUVDWWDFKHGLQWKHZKLWHSODVWLF
3XVKLQZDUGVWKHPRWRUODPSFRQQHFWRUVXQWLOWKHORFNLQJV\VWHPRQ
connectors is well attached.
&RQQHFWKRRGWRSRZHUVXSSO\DQGYHULI\
TROUBLESHOOTING