Venting Methods
This range hood is factory set for venting through the roof or
through the wall. You can apply the recirculating venting method
by purchasing the Recirculation Kit.
The vent system needed for installation is not included.
A6”(15.2cm)roundventsystemisrecommended.
Roof Venting
A.6”(15.2cm)vent
through the roof
B. Roof cap
Wall Venting
A.6”(15.2cm)vent
through the wall
B. Wall cap
Recirculating
A.6”(15.2cm)vent
through the cabinet
B. Round recirculating grid
Calculating Vent System Length
Therecommendedventsystemis6”(15.2cm)roundventwitha
maximumlengthof35ft(10.7m).Forthebestperformance,use
no more than three 90° elbows.
To calculate the length of the system, add the equivalent feet
(meters)foreachoftheventpiecesusedinthesystem.
Vent Piece 6” (15.2 cm)
45° elbow 2.5 ft
(0.8m)
90° elbow 5.0 ft
(1.5m)
Example Vent System
90° elbow
Wall cap
2ft(0.6m)
6ft(1.8m)
Maximum Recommended Length = 35 ft (10.7 m)
1-90°elbow =5.0ft(1.5m)
1-wallcap =0.0ft(0.0m)
9ft(2.8m)straight =9.0ft(2.8m)
Length of 6” (15.2 cm) system = 14.0 ft (4.3m)
WARNING
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, re, or electrical shock.
IMPORTANT: The range hood must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
(latestedition)orCanadianElectricalCode,CSAC22.1
No.0-M91(latestedition).
If codes permit and a separate ground wire is used, it is
recommendedthataqualiedelectricalinstallerdeterminethat
the ground path is adequate.
Electrical Requirements
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy,MA02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland,Ohio44131-5575
A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required.A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range hood be provided.
This range hood is equipped with a power supply cord having
a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outletinstalledbyaqualiedelectrician.